Know more about how to install LVT flooring ?

Pre-installation considerations
 
    1, floor pavement should be in the ground concealed works, ceiling works, wall works, hydropower projects completed and acceptance after.
 
    2, the scene without cross-construction phenomenon, and no special construction restrictions.
 
    3, the requirements of the ground: clean (no obvious construction waste, etc.), dry (refers to the ground humidity should be less than 20%, not wet or leakage), flat (2M by foot detection of ground flatness, The maximum string height of the ground should be ≤ 3mm), solid (ground foundation strength and thickness should be consistent with the provisions of housing acceptance).
 
    4, corner of the reserved height: lock-type moisture-proof mat 3mm, floor height 11mm, a total of 14mm, according to the cork flooring and other ground contact parts higher than the floor height of the finished product to be properly reserved, especially the door, , Heating hoods and other irregular details, should also be dealt with.
 
    5, the partition problem: lock cork flooring continuous laying up to 7 - 8 meters, longer than this distance will be pressed to cut off the bar.
 
    6, loss: the loss of the floor according to the size of the room, shape, there are no shaped (such as the platform, cut off, etc.) and so on, in general, the room Founder, large loss of small, in general, less than 5% For 3 --- 5%, the loss of individual shaped structure may exceed 5%.
 
Install before installation
 
     1.Before installation, the ground should be clean, dry, stable, smooth, before installation to make up for irregularities.
 
    2. If the wood on the ground to do the wooden keel shop big core board need to use wooden screws to the wood keel core plate fixed stable and solid, and between the board and the board reserved 8mm telescopic gap (door and stalk, please do not leave the expansion joints) And finally to smooth dry and no noise can be.
 
 
    3. In order to achieve better results, the floor can be paved with most of the light outside the window.
 
     4.Door and door cover and wood floor connection: the door and the door under the reserved wood floor thickness, the door reserved below 14mm, the door set aside l2mm.